Contact ratio factor

Symbol Xε
Unit -
Attribute-ID iso_6336_20_21_contact_ratio_factor_combo
Numeric ID 19579
Value Type PMString

The contact ratio factor Xε converts the flash temperature value at the effective tip diameter of the pinion, when load sharing is neglected, to a mean value of the flash temperature over the path of contact.

The following options are available:

  1. User specified
    Direct numerical input

  2. Acc. to ISO 6336 part 20/21

The contact ratio factor can be expressed in terms of addendum contact ratios ε1 and ε2 and their sum εα. The formulae for Xε are based on an assumed linearity of the flash temperature over the path of contact (ISO6336-21:2022 clause 6.1.14 formula 40-46).