| Symbol | - |
|---|---|
| Unit | - |
| Attribute-ID | agma2101c95 application conditions Z_N |
| Numeric ID | 1129 |
| Value Type | PMInteger |
If ZN is not directly specified, the factor IS determined according to Figure 17 (AGMA 2101-D04). The number of load cycles as well as the material properties are essential.
If the number of load cycles is in the endurable fatigue area, the limit curve can be selected by choosing "critical applications" or "general applications."