| Symbol | - |
|---|---|
| Unit | - |
| Attribute-ID | agma_method_k_v |
| Numeric ID | 4894 |
| Value Type | PMString |
The dynamic factor Kv takes into account the impact of internal dynamic forces that are caused by non-uniform rotary transmission. Kv is used for flank and root calculations.
Instead of the dynamic factor, grade of the gear ratio accuracy Av, or the adjacent pitch error fpt can be specified. This is then used to determine the dynamic factor.