| Symbol | cγ |
|---|---|
| Unit | N/(mm·µm) |
| Attribute-ID | mesh stiffness |
| Numeric ID | 1063 |
| Value Type | PMTechValue |
Specification of whether the mesh stiffness according to DIN 3990, ISO 6336, or a user specification should be used for calculation of the load distribution across the facewidth in the entire system.
KA= 1.0 and Kγ = 1.0 are used for calculation of cγ according to DIN/ ISO.