| Symbol | BM |
|---|---|
| Unit | N/(m·√s·K) |
| Attribute-ID | iso_6336_20_21_thermal_contact_coefficient |
| Numeric ID | 8457 |
| Value Type | PMTechValue |
The thermal contact coefficient BM is directly included in the calculation of the thermal flash factor XM, which in turn is used in the calculation of the flash temperature Θfl.The following options are available:
(ISO6336-20:2022 clause A.4 formulas A.11-12)