Sliding safety (axial force only)

Symbol SR,ax
Unit -
Attribute-ID sliding_safety_axial_force
Numeric ID 19330
Value Type PMDouble

For combined loads, an ellipsoidal relationship results for the transmission range of the interference fit in the joint from the validity of Coulomb's law of friction (cf. among others Final Report FVA 312-I Section 6.5). The combined sliding safety of a tapered interference fit is determined by

or

The bending moment section is omitted for cylindrical and multiple interference fit connections.